Tiger XTL Portable VOC Gas Detector
The Tiger XTL portable VOC gas detector is a variant of the hugely popular Tiger, but low on cost and high on performance. The portable VOC gas detector utilizes revolutionary, patented photoionization detection (PID) sensor technology with humidity resistance. The anti-contamination design provides market-leading accuracy and run-time for any gas detection scenario.
- Improved robust design can withstand harsh environments
- IP65 ingress protection against a range of weather conditions
- <2 second response time, one of the fastest and most accurate on the market
- Instantaneous alarms, RED & AMBER with loud 95 dBA sounder
- Humidity resistant and
- anti-contamination design ensures optimal performance
Free Shipping On All Orders (2-5 days)
30 Days Money Back & One Year Warranty
Built-in Privacy & Security Protection
The Tiger XTL portable VOC gas detector offers simple, one-handed operation even when wearing the thickest of gloves. The Tiger XTL has a thermo plastic elastomer outer moulding, this rubber material is semi-conductive making the Tiger XTL intrinsically safe.
The large, clear backlit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. The illuminated keypad activates when the light is low.
The Tiger XTL has a push to release button for the rechargeable battery allowing for quick, easy and secure battery connection.
Specification |
Value |
---|---|
Minimum Resolution* | 0.1 ppm |
Maximum Reading | 5,000 ppm |
Response Time | T90 < 2 seconds |
Accuracy* | ± 5% display reading ± 1 digit |
Linearity* | 5% display reading ± one digit |
Intrinsically Safe Approvals | II1GExiaIICT4Ga Tamb = -25 oC ≤Ta ≤+45 oC (with Lithium ion Battery Pack) Tamb = -25 oC ≤Ta ≤+40 oC (with Alkaline Battery Pack) IECEx ITS 22.0025X ITS-I22ATEX35111X ITS22UKEX0635X 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1. Class 1 Division 1. Approval for groups A, B, C & D, T4. |
Battery Life | Typical operating time of 24 hours Typical charge time of 8 hours |
Lamps | 10.6 eV Krypton PID lamp (standard) |
Data Logging* | Push-to-log, 128 zones, 80,000 data points |
Calibration | Standard calibration 100 ppm isobutylene Custom calibration capability |
Alarm | Flashing LED and 95 dBA at 300mm (12”) audible sounder selectable vibrating alarm |
Flow Rate | ≥ 220 ml/min in ambient conditions (with blocked flow alarm) |
Humidity | 0-99% RH (non condensing) |
Protection | Designed to IP65 EMC tested to EN61326-1:2013, EN50270:2015 & CFR 47:2008 Class A |
Weight & Dimensions | 370 mm (H) x 91 mm (W) x 60 mm (D) 870g |