Titan 2 Fixed Gas Monitor
Titan 2 benzene gas monitor incorporates the NEW MiniPID T2 10.0 eV Sensor which offers improved sensitivity, reliability and overall performance. The unique sampling method eliminates interfering gases such as toluene, xylene and methane providing you with accurate benzene concentration readings you can rely on.
- New MiniPID T2 10.0 eV Sensor – Unique to Titan 2.
- Low Detection Limit – Can detect benzene down to 0.02 ppm (20 ppb).
- IP65 – Protection against a range of atmospheric conditions.
- Interchangeable Service Module – plug and play cartridge.
- 4-20 mA & RS485 Communication Options – Connect to your own control system.
Free Shipping On All Orders (2-5 days)
30 Days Money Back & One Year Warranty
Built-in Privacy & Security Protection
Titan 2 offers a world leading solution for the detection of benzene, providing precise detection at levels as low as 0.02 ppm (20 ppb) and as high as 20 ppm within 60 seconds. Titan 2 benzene gas monitor has been specifically engineered to analyze airborne dangers and can be utilized to evaluate the efficiency of purification or vapor recovery systems/units (VRU).
Titan 2 benzene gas monitor has obtained certification for use use in ATEX zoned environments and locations. Furthermore, the enclosure is IP65 rated, offering reliable protection against the intrusion of dust and water.
Benzene is a highly toxic and carcinogenic chemical that can cause both short-term and long-term effects on workers who are exposed to it. The most significant health risks associated with long-term benzene exposure is the development of leukemia, specifically acute myeloid leukemia (AML).
Titan 2 delivers unrivalled accuracy and sensitivity in benzene detection and is ideal for use in a variety of sectors such as oil and gas, bulk storage facilities, chemical manufacturing and processing and asphalt production.
Technical Specification
Specification | Value |
Sensor Type | MiniPID T2 10.0 eV Sensor |
Sensitivity | Benzene specific within typical petrochemical matrix |
Detectable Range | 0.02 ppm – 20 ppm |
Measuring Frequency | One Minute |
Lower Level of Detection | 0.02 ppm (20 ppb) (10 ppb resolution) |
Accuracy | +/- 50 ppb or +/- 10%, whichever is greater* |
Temperature Stability | Internally heated |
Flow Rate | Sample flow rate ≥ 100 ml/min |
Display |
Graphic BW LCD 64 x 128 pixels with backlight Bright LEDs for normal operation, fault and alarm Two magnetic switches for menu operation |
Operating Temperature | Recommended operating range of -20 oC to +50 oC (-4 oF to +122 oF) for optimum performance** |
Approvals |
4FTZU 14 ATEX 0172X IECEx FTZU 14.0030X QPS LR1621-1 |
Ingress Protection Rating | IP65 |
Humidity | 0 – 99 % RH |
Minimum Service Period | 6 months – PID lamp, electrode stack, inline filter, VRV restrictor, Hydrophobic & carbon filter replacement 12 months – PID lamp, electrode stack, inline filter, VRV restrictor, hydrophobic & carbon filter, Airsep filter |
Cable Entry | Two ¾ NPT gland threads |
Power Requirements | Vin (nom) 24 V DC @ 3.2 A (recommended) Vin (max) 32 V DC @ 2.4 A Vin (min) 19 V DC @ 4.0 A |
Communication | Isolated 4-20 mA output Isolated RS 485 Modbus connection via ASCII or RTU (simplex/half duplex or fully duplex) Micro USB (PC Software) |
Data Storage | On board MMC, minimum of six months (2GB) |
Relay Output | Two isolated outputs, voltage free, 24 v DC @ 1.25 A |
Weight and Dimensions | 15 kg (33 lbs) 219 x 219 x 172 mm (8.6 x 8.6 x 6.8” approx.) |
Gas Sample Line | 10 m max length, PTFE, 6 mm OD, 4 mm ID |